[Free] 2018(Mar) EnsurePass Passguide VMware VCP510PSE Dumps with VCE and PDF Download 71-80

Ensurepass.com : Ensure you pass the IT Exams 2018 Mar VMware Official New Released VCP510PSE
100% Free Download! 100% Pass Guaranteed!
http://www.EnsurePass.com/VCP510PSE.html

VMware Certified Professional on vSphere 5

Question No: 71 – (Topic 2)

Which network settings are only available with vSphere Distributed Switches?

  1. Jumbo Frames

  2. PVLAN

  3. Load Balancing

  4. Promiscuous Mode

Answer: B Reference:http://kb.vmware.com/selfservice/microsites/search.do?language=en_USamp;cmd= displayKCamp;externalId=1010691

Question No: 72 – (Topic 2)

When wouldan administrator configure the Explicit Failover option for a portgroup created on a virtual switch with multiple uplinks?

  1. To manually configure load balancing for the portgroup

  2. To share uplinks between vSwitches

  3. When configuring iSCSI Software Initiator multipathing

  4. If the physical switch does not support etherchannel or 802.3ad

Answer: C Reference:http://www.epubbud.com/read.php?g=8MVD69ZNamp;tocp=15(see the paragraphbelow figure 5.2)

Question No: 73 – (Topic 2)

Which two features secure the VMkernel? (Choose two.)

  1. Memory Encryption

  2. Hardware assist virtualization

  3. Kernel module integrity

  4. Trusted Platform Module (TPM)

Answer: C,D

Reference:http://searchvmware.techtarget.com/tip/VMware-ESXi-security-Protecting-VMs- VMkernel-and-the-network(see ‘Guard the VMkernel’)

Question No: 74 – (Topic 2)

A vSphere Standard Switch has been configured for IP-based load balancing using two uplinks. A new uplink is added to the vSwitch.

What is the status of the uplink by default?

  1. The uplink is placed instandby mode until it is added to the active NIC team.

  2. The uplink is marked as active but does not participate in the active NIC team until assigned to a port group.

  3. The uplink is marked as active, but cannot be used by the active NIC team until it is added to the existing 802.3ad group on the physical switch.

  4. The uplink is marked as unused until it is added to the active NIC team.

Answer: C Explanation:

The new uplink will be marked as active but it cannot use active NIC team until it is added toan existing 802.3ad group on the physical switch.

Reference:http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01990371/c0199

0371.pdf(page 26onwards)

Question No: 75 – (Topic 2)

Which two statements are true regarding vSphere virtual switch uplinks? (Choose two.)

  1. vSphere virtual switches do not need to be configured with an uplink.

  2. Multiple vSphere virtual switches can be configured to use the same uplink.

  3. vSphere virtual switches must be configured with at least one uplink.

  4. Multiple vSphere virtual switches cannot be configured to use the same uplink.

    Answer: A,D Explanation:

    VMware Virtual Networking Concepts, page 6. Some virtual switches should not connect to a physical network and thus have no uplink port. If you attempt to assign an uplink port, (previously assigned to a switch), to a second switch, the uplink will be disconnected from the first switch before being connected to the second.

    Ensurepass 2018 PDF and VCE

    Question No: 76 – (Topic 2)

    A virtual machine, VM21, will be migrated between two ESXi 5.x hosts, labeled ESXi01 and ESXi02. Each host has two vSphere Standard Switches (vSS), configured as follows:

    1. vSwitch0 has a portgroup labeled Management and aportgroup labeled vMotion.

    2. The Management portgroup contains a vmkernel port tagged for management traffic.

    3. The vMotion portgroup contains a vmkernel port tagged for vMotion traffic.

    4. vSwitch0 on ESXi01 has a single uplink attached to the10.1.20.0/24 network.

    5. vSwitch0 on ESXi02 has a single uplink attached to the 10.1.20.0/24 network.

    6. Each host has a vSwitch1 with a Production portgroup used by virtual machine traffic.

    7. Each vSwitch1 has an uplink attached to the 10.1.40.0/24 network. What is true about migrating VM21 to the new host?

      1. vMotion would be supported in this configuration.

      2. Storage vMotion would not be supported in this configuration.

      3. vMotion would not be supported in this configuration.

      4. Storage vMotion wouldbe supported if the storage device supports VAAI.

Answer: A Explanation:

As per the configuration shown in the question, vmotion will be supported without any problem.

Question No: 77 – (Topic 2)

Click the Exhibit button.

Ensurepass 2018 PDF and VCE

An administrator has been tasked with adding a newly installed uplink to vSwitch1. Based on the exhibit, what is a true statement about this environment?

  1. The server does not have available vSwitches to be assigned to this uplink.

  2. The available uplinks are not compatible with astandard vSwitch.

  3. The host needs a driver installed for the newly installed uplink.

  4. The current uplinks cannot be attached because they are in use by other port groups.

Answer: C

Explanation: as you can see that the Next button is greyed out. This means the host needs driver installed on the newly installed uplink. Once the driver in installed, the Next button will become active.

Question No: 78 – (Topic 2)

Which settings are required for virtual machine guest tagging for VLAN 100 in a vSphere

5.x environment?

  1. Port Group configured for VLAN 100, physical switch configured as a VLAN trunk

  2. Port Group configured for VLAN 4095, physical switch configured as a VLAN trunk

  3. Port Group configured for VLAN 100, physical switch configured for VLAN 100

  4. Port Group configured for VLAN 4095, physical switch configured for VLAN 100

Answer: B Explanation:

A VLAN ID, which restricts port group traffic to a logical Ethernet segment within the physical network, is optional. For a port group to reach port groups located on other VLANs, the VLAN ID must be set to 4095. If you use VLAN IDs, you must change the port group labels and VLAN IDs together so that the labels properly represent connectivity.

If you enter 0 or leave the option blank, the port group can see onlyuntagged (non-VLAN) traffic. If you enter 4095, the port group can see traffic on any VLAN while leaving the VLAN tags intact.

Question No: 79 – (Topic 2)

When you are configuring the NIC teaming policy for a vSwitch, what happens when the Failback option is set toYes?

  1. A failed uplink will be left inactive upon recovery until another uplink fails.

  2. The vswitch is notified when a failover event occurs.

  3. The physical switches are notified when a failback event occurs.

  4. A failed uplink is returned to activeduty immediately upon recovery.

Answer: D

Explanation: Select Yes or No to disable or enable failback.This option determines how a physical adapter is returned to active duty after recovering from a failure. If failback is set to Yes (default), the adapter isreturned to active duty immediately upon recovery, displacing the standby adapter that took over its slot, if any. If failback is set to No, a failed adapter is left inactive even after recovery until another currently active adapter fails, requiring its replacement.

Question No: 80 – (Topic 2)

Which three features are only available in the vSphere Client when using a vSphere Distributed Switch? (Choose three.)

  1. Port Mirroring

  2. PVLAN tagging

  3. Storage I/O Control

  4. Ingress Traffic Shaping

  5. 802.1q VLAN Tagging

Answer: A,B,D

Reference:http://pubs.vmware.com/vsphere-51/topic/com.vmware.ICbase/PDF/vsphere- esxi-vcenter-server-51-networking-guide.pdf

100% Ensurepass Free Download!
Download Free Demo:VCP510PSE Demo PDF
100% Ensurepass Free Guaranteed!
Download 2018 EnsurePass VCP510PSE Full Exam PDF and VCE

EnsurePass ExamCollection Testking
Lowest Price Guarantee Yes No No
Up-to-Dated Yes No No
Real Questions Yes No No
Explanation Yes No No
PDF VCE Yes No No
Free VCE Simulator Yes No No
Instant Download Yes No No

Leave a Reply

Your email address will not be published. Required fields are marked *